Fire resistance directory gcp applied technologies ul designs fireresistance ratings ansi ul 263 rate. Exterior fireresistance rated walls for more information visit. Authorities having jurisdiction should be consulted before construction. V455 fire resistance ratings ansiul 263 designsystem. Consult the factory mutual research corporation approval guide. For nearly 60 years, architects, designers and code authorities have relied on ul fireresistancerated wall, floor ceiling, roof ceiling, and column and beam designs for codecompliant installations. Ul 263 standard for fire tests of building construction and. Rapidrise fire test fire resistance designs for protecting structural members subject to petrochemical exposure fires are investigated according to ansi ul 1709, rapid rise fire tests of protection materials for structural steel, and are covered under fire resistance ratings ansi ul 1709 bybu. National fire protection association 1 batterymarch park p. Ul fire resistance complete document 2015 edition, 15.
Fsone high performance intumescent firestop sealant. The fireresistance rated wall assemblies published under the u, v and w series of designs on the ul online certifications directory are intended for interior applications unless otherwise specified or implied in the design. The different types of fire resistance assemblies fras including wall, ceiling, and floor assemblies. Tsn is dedicated to producing the highest quality light steel framing and connectors. Floorceiling acoustical assemblies1 roofceiling acoustical assemblies1 type of construction maximum time rating hrs ulc design number concrete thickness mm panel or tile size mm panel or tile type2 edge detail allowed3 panel or tile thickness.
This article focuses on products ul certifies for protecting membrane penetrations in these walls. Fireresistance ratings shall be determined in accordance with. See fire resistance directory roofing membrane chci. Ulc standards develops and publishes standards and specifications for products having a bearing on fire, life safety and security, crime prevention, energy efficiency, environmental safety, security of assets and facilities, live working and workplace safety. Bxuv fireresistance ratings ansiul 263 see general information for fireresistance r atings ansiul 263 design no. Fireresistance rated hwd assemblies are identified in the ul fire resistance directory, which can be found at the underwriters laboratories website at. Fire resistance directory gcp applied technologies ul designs fire resistance ratings ansi ul 263. Fire ratedfire resistance ratings have long been used by ul, astm and building codes to measure the performance of various constructions for fire containment purposes. Document 1, from the ul online fire resistance directory, shows an example of the construction of this type of. Exterior fire resistance rated walls for more information visit. Bxuv fire resistance ratings ansiul 263 cer tified for united states bxuv7 fire resistance ratings canulcs101 cer tified for canada see general information for fireresistance ratings ansiul 263 certified for united s tates design criteria and allowable variances. As applied to elements of buildings, the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated. Document 1, from the ul online fire resistance directory, shows an example of the construction of this type of assembly.
Ul 263 standard for fire tests of building construction. The gypsum association fire resistance design manualis. For the most uptodate fire resistance ratings, refer to the ul online certifications directory, ul u415. In addition, the manual has been recognized in major jurisdictions in canada. Additional beam and joist substitution requirements are in the front of the fire resistance directory iii. The ul certification mark on fire resistant products, systems and assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements. Fire resistance rated wall assemblies are relied upon to help provide safety to life and property from fire, products of combustion, and similar hazards. The published information cannot always address every construction nuance encountered in the field. Ad firebarrier putty pads for use with max 2316 by 334 by 212 in. Fireratedfireresistance ratings have long been used by ul, astm and building codes to measure the performance of various constructions for fire containment purposes. Methods for determining fire resistance the application of any of the methods listed in this section shall be based on the fire exposure and acceptance criteria specified in astm e119 or ul 263. Wall to be constructed in the individual u400 or v400 series design in the ul fire resistance directory, except that a nom 1 in.
Underwriters laboratories of canada ulcworking for a safer world to summarize ul and ulc strive to bring the most current and accurate information available for fire resistance designs and to confirm with clarity, that the products on the. We provide a wide range of publications that include the information you need to provide safe, sustainable code compliant installations. Anyone know of a source for ul fire resistance details in autocad. In lieu of item 2, roof covering consisting of singleply roofing membrane that is either ballasted, adhered or mechanically attached as permitted under the respective manufacturers classification. Bxuv fire resistance ratings ansiul 263 certified for united. For use in troughpenetration firestop systems see ul fire resistance directory 66y7 firestop device for use in throughpenetration firestop systems see ul fire resistance directory 5n76 castin firestop devices cp 680p and cp 680m for use in dust and fiber free environments such as. Ul 1479 astm e 84 cfspl only see hilti literature or thirdparty listings for complete application and installation details fill, void or cavity material for use in throughpenetration firestop systems see ul fire resistance directory 66y7. See fire resistance directoryroofing membranes chci. As applied to elements of buildings, the fireresistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fireresistance rated. Bxuv fire resistance ratings ansiul 263 cer tified for united states bxuv7 fire resistance ratings canulcs101 cer tified for canada. In order to provide the anticipated hourly fire resistance rating these assemblies must be constructed and maintained in accordance with their design criteria e. Chip harper member of the autodesk discussion forum moderator program. Standard for surface raceways and fittings for use with data, signal, and control circuits. Newsletters for code authorities ul quarterly newsletters provide code authorities with relevant technical articles and timely updates on ul developments that can enhance your ability to approve safe, sustainable code compliant installations.
For the most uptodate fireresistance ratings, refer to the ul online certifications directory, ul u415. Fire resistance directory gcp applied technologies ul designs fireresistance ratings ansiul 263 rate. Underwriters laboratories is a nonprofit organization dedicated to advancing the ul mission through the discovery and application of scientific knowledge. Being able to visually see how and when the ul directory is applied will save you time, money, and frustration. Exterior fireresistance rated walls ul code authorities. We conduct rigorous independent research and analyze safety data, convene experts worldwide to address risks, share knowledge through safety education and public outreach initiatives, and. Ulc standards is accredited by the standards council of canada as a.
More than 1,500 designs are currently available through ul s fire resistance directory or online certifications directory. Only products which bear uls mark are considered as classified, listed, or recognized. Partition assemblies, of the fire resistance design information section of the ul online certifications directory. Guide information for electrical equipment the white book 201516 ul product categories correlated to the 2011 and 2014 national electrical code uls general guide information is updated daily. Usg fireresistant assemblies catalog english sa100.
Horizontal butt joints on opposite sides of the studs in singlelayer applications should be staggered a minimum of 12 in. Outline of investigation for pump tank extinguishers. For use in troughpenetration firestop systems see ul fire resistance directory 66y7 firestop device for use in throughpenetration firestop systems see ul fire resistance directory 5n76 castin firestop devices cp 680p and cp 680m for use in dust and fiber free environments such as hospitals, computer. V455 march 03, 2010 nonbearing wall rating 1 and 2 hr bxuv. Rapidrise fire test fireresistance designs for protecting structural members subject to petrochemical exposure fires are investigated according to ansiul 1709, rapid rise fire tests of protection materials for structural steel, and are covered under fireresistance ratings ansiul 1709 bybu. Newsletters for code authorities ul quarterly newsletters provide code authorities with relevant technical articles and timely updates on ul developments that can enhance your ability to approve safe, sustainable code compliant. Underwriters laboratories of canada ulcworking for a safer world to summarize ul and ulc strive to bring the most current and accurate information available for fire resistance designs and to confirm with clarity, that the products on the ul and ulc directories comply with canadian requirements.
Ul standards list ul standards directories ul product. More than 1,500 designs are currently available through uls fire resistance directory or online certifications directory. An overview of the building code and ul fire resistance directory. Ul fire resistance directory, except that a max 34 in. Only products which bear ul s mark are considered certified. Ulc standards develops and publishes standards and specifications for products having a bearing on fire, life safety and security, crime prevention, energy efficiency, environmental safety, security of assets and facilities, live working and workplace safety and other areas. Only products which bear uls mark are considered certified. Bxuv fire resistance ratings ansi ul 263 cer tified for united states bxuv7 fire resistance ratings canulcs101 cer tified for canada see general information for fire resistance ratings ansi ul 263 certified for united s tates design criteria and allowable variances. Fire resistance ratings ansiul 263 see general information for fire resistance ratings ansiul 263 design no. It is a key differentiator for products within the exterior wall assembly market. For nearly 60 years, architects, designers and code authorities have relied on ul fire resistance rated wall, floor ceiling, roof ceiling, and column and beam designs for codecompliant installations. Wall assembly the 1 or 2 hr firerated gypsum boardstud wall assembly shall be constructed of the materials and in the manner described in the individual u300, u400 or v400 series wall and partition designs in the ul fire resistance.
Ul fire resistance directory pdf kissing hand book free online, the ul fire resistance directory set is the ultimate reference source for a wide range of fire resistance rated assemblies, designs, and products. See ul fire resistance directory for complete design details. Fireresistive floorceiling assemblies fire engineering. The hourly fire rating of the joint system is equal to the hourly fire rating of the wall. The title of the standard used to investigate the product if there is a published ul standard or for international directories an appropriate international or regional standard for the specific product category. Most backordered items can be rushed in from the publisher in as little as 24 hours.
Electrical rigid metal conduit aluminum, red brass, and stainless steel. Membrane penetrations in fireresistance rated walls. Ul design u419 1, 2, 3 or 4 hour wall assembly installation instructions ul systems. Box 9101 quincy, massachusetts 022699101 see nfpa 90a, nfpa 101, nfpa 221, nfpa 5000, and the life safety code handbook the fire resistance design manualis also referenced in the code documents of. Roofing materials and systems directoryroof covering materials tevt.
The required fire resistance of a building element, component or assembly shall be permitted to be established by any of the following methods or. Covers hourly fire ratings for beams, floors, roofs, columns, walls and. Floorceiling acoustical assemblies1 roofceiling acoustical assemblies1 type of construction maximum time rating hrs ulc design number concrete thickness mm panel or tile size mm panel or tile type2 edge detail allowed3 panel or tile thickness mm minimum. V335 fireresistance ratings ansiul 263 designsystem. Fire resistance directory underwriters laboratories. Estimated range of acoustical performance is based on laboratory test data of similarly constructed assemblies. V455 fire resistance ratings ansiul 263 page bottom. Structural fire resistance and fireresistancerated construction. The purpose of this pdf library is to enable engineers, designers, and contractors to easily access. See roofing materials and systems directory roof covering.
1109 1325 1337 1195 83 276 1280 1437 655 874 348 383 953 1502 129 283 1439 399 690 965 1095 1411 149 695 297 1142 73 346 552 143 94 895 1278 1616 593 1216 1297 84 1383 305 120 724 410 1067 1038